CE marking gearmotor

CE marking gearmotor

Description of the type

GTR-MINI 15W~90W

Description of the type

GTR-MID 0.1kW~2.2kW

Description of the type

GTR-MID 0.1kW~2.2kW

Description of the type

MID Series Compatible Standards

Voltageand CertificationCode Description Voltage/Frequency Compatible Standard
NN StandardVoltage(SameasJapaneseDomesticType) 200V/50Hz、200V/60Hz、220V/60Hz UL・CE・CCC
WN StandardVoltage(SameasJapaneseDomesticType)HighVoltage(400VClass)(SameasJapaneseDomesticType) 380V/50Hz、400V/50Hz、400V/60Hz、440V/60Hz UL・CE・CCC
KN Special voltage (dual voltage) South Korea and Taiwan 220V/60Hz、380V/60Hz UL・CE・CCC
CN Special voltage (dual voltage) China 220V/50Hz、230V/50Hz、380V/50Hz UL・CE・CCC
DN Special voltage (dual voltage) China, South Korea and Taiwan 220V/50Hz、220V/60Hz、380V/50Hz、380V/60Hz UL・CE・CCC
EN Special voltage Europe and North America 415V/50Hz、440V/50Hz、480V/60Hz UL・cUL・CE・CCC
UN Special voltage (dual voltage) North America and Europe 230V/60Hz、460V/60Hz、400V/50Hz UL・cUL・CE・CCC
AN Special voltage (dual voltage) North America and Europe 208V/60Hz、230V/60Hz、460V/60Hz、400V/50Hz UL・cUL・CE・CCC
MA Special voltage Canada 575V/60Hz UL・cUL

What is CE marking

Machines to be exported to Europe require "CE marking."
It is obligated to conform to the EC Directive for CE marking
In principle, certification of conformity to the EC Directive requires conformity to the EN standard.

CE mark

Applicable directive/Applicable standard

EC DirectiveLow Voltage Directive 2014/35/EU
EN standard EN60034-1 (provision for motors in general)

Technical Documentation : Ecodesign Directive Power Loss Data

Ecodesign Directive Power Loss Data(Commission Regulation(EU)2019/1781)

Target Models:3-Phase Induction Gearmotor 0.2kW to 2.2kW

Efficiency class:IE2(0.2kW to 0.4kW)、IE3(0.75kW to 2.2kW)